Product Details : WINDOW AIR CONDITIONER TRAINER

WINDOW AIR CONDITIONER TRAINER

Product Name :

WINDOW AIR CONDITIONER TRAINER

   

Catalog No :

R.A.C 52

 

DESCRIPTION :

WINDOW AIR CONDITIONER TRAINER:-

DESCRIPTION:-

This unit consists of a hermetically sealed compressor with air cooled condenser. A capillary are next to condensers followed by medium temperature evaporators. Electrical energy supplied to the compressor can be measured by energy meter.

EXPERIMENTS:-

  • Ø To calculate the COP of unit.             
  • Ø To calculate the refrigerating effect and HP of unit.
  • Ø To determine the sensible heat factor of air.

TECHNICAL SPECIFICATION: -

  • Electrical Control      :           Main Switch, Voltmeter Digital type, Amp. Meter Digital Panel type,

Energy Meter for Compressor input.

  • Digital Temperature:Provided with RTD thermocouple for various temperature
  • MS Stand: The unit shall be assembled on heavy duty Angle Iron Base
  • Voltage : Single Phase 220 Volts 50Hz. AC Supply
  • Manual : Operation and maintenances manual should be provided along with the supplied Equipment.
  • The whole Set-up is mounted on a sturdy frame with control panel.                                                          

Technical Specification

Description

Compressor

1 Ton Emerson Hermetically sealed compressor shall be provided with its standardized accessories.

 

Condenser

Fined Tube type air cooled condenser with variable speed fan Best Indian make.

Evaporator                                      

Fins and Copper tube type cooling coil of suitable capacity fitted in the unit Best Indian make.

 

Refrigeration

Freon R – 22

 

Fan Blower Set

Standard make.

 

Refrigeration Control Panel

a). Sight glass  to the flow of liquid refrigerant gas

b).Capillary tube expression devices.

c). Filter cum Drier     

d). Suction pressure gauge for low-pressure measurement

e). Discharge pressure gauge for height- pressure measurement

 

Electrical Control

Main Switch, Voltmeter Digital type, Amp. Meter Digital Panel type, Energy Meter for Compressor input.

 

Digital Temperature

Provided with RTD thermocouple for various temperature

MS Stand                                         

The unit shall be assembled on heavy duty Angle Iron Base

Voltage                                             

Single Phase 220 Volts 50Hz. AC Supply

 

Manual

Operation and maintenances manual should be provided along with the supplied equipment.

 


 